Model: KXS series X-ray generator
Power: 10W - 50W
Input voltage: DC24V
Output voltage: 10kV, 20kV, 30kV, 40kV, 50kV
Electrical input and output parameters:
Input voltage: DC 24V
Input current: 2.5A (Max)
Output high voltage: 0- +30KV
Output current: 0- 1mA
Filament voltage: DC 0- 4 V
Filament current: 0 - 4A
Reference settings:
When the device is in local mode, the device has 2 potentiometer groups to set the output high voltage and current, GROUP1 is high level (24V), GROUP1=24V channel setting is valid, GP1 is low level (0V ), GROUP1=0V channel setting is valid. The output high voltage can be individually set as required.
Precautions:
Because this equipment can generate high voltage, which is dangerous to the human body, it is strictly forbidden for untrained personnel to operate the equipment.